The individual virtual eye

DSpace Repository

Show simple item record

dc.contributor.advisor Straßer, Wolfgang (Prof. Dr.-Ing. Dr.-Ing. E.h.) de_DE
dc.contributor.author Einighammer, Jens de_DE
dc.date.accessioned 2008-04-10 de_DE
dc.date.accessioned 2014-03-18T10:18:25Z
dc.date.available 2008-04-10 de_DE
dc.date.available 2014-03-18T10:18:25Z
dc.date.issued 2008 de_DE
dc.identifier.other 279002785 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-33012 de_DE
dc.identifier.uri http://hdl.handle.net/10900/49149
dc.description.abstract The individual virtual eye is a computer model of a human eye with respect to the optical properties. Established schematic eyes, as Gullstrand’s model eye, are intended to represent properties of an average eye based on averaged population measurements. In contrast, the individual virtual eye is based on measurements of an individual person. Therefore the geometry of the eye is important, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye – an eye with an artificial lens – are modeled by means of computer scientific methods. A spline-based interpolation method was developed to efficiently include data from corneal topographic measurements. Based on this virtual eye the geometrical optical properties, such as the wavefront aberration, can be simulated by using Snell’s law of refraction and the method called real ray tracing. Moreover, optical components can be calculated using computer scientific optimization procedures. High value was set on the efficient implementation of the time-critical numerical ray-tracing and optimization procedures to allow for short calculation times in the range of seconds. This leads to clinical application fields in ophthalmology that have been addressed in this thesis. One application is intraocular lens calculation for cataract surgery, with the potential to overcome limitations of current calculation methods like lens calculation after refractive surgery. Also customized aspherical lenses were calculated what shows the capability of the methods to deal with advanced lens geometry. Clinically important issues as the optical effects of intraocular lens dislocation have been investigated. Furthermore, this computer model has been used to assess ablation profiles used in current refractive corneal laser surgery. One possible future enhancement of the model is the simulation of phakic eyes by incorporating a correct model of the human crystalline lens. And, so far, the individual virtual eye focused on geometrical optical properties, but may serve as a basis for including physiological properties of the retina and brain in future. Errata (last revised August 4, 2009) * Section 2.1, page 11, line 3 f.: Change Zernike specifications to "Z(0,0) is known as [...]" and "Z(1,-1) and Z(1,1) are known as [...]". * Section 2.2, page 18, line 8 ff.: Shorten sentence to "Figure 2-12 gives an overview of different values of the asphericity Q and the corresponding shapes.". * Section 4.4, page 52, line 19 ff.: Change text to "However, according to Applegate et al. [...] as well as high and low contrast visual acuity [...]". * Section 5.2, page 76, Figure 5-16: The numbers of the "Theoretical" bars are wrongly specified with comma instead of decimal points; change numbers to "0.04", "0.06", "0.20" and "0.32". * Section 5.2, page 77, line 18 ff.: At the end of the sentence "When interpreting the diagrams [...]", in the formula for "SA RMS", exchange the multiplication symbol "·" with a plus symbol "+". * Section 5.2, page 81, Table 5-6: The assignment of the anterior and posterior surface in the header of the table is wrong. Correct is that the label "Anterior Surface" combines the 3rd and 4th column "Rflat" and "Rsteep" while the label "Posterior Surface" only refers to the 5th column "Q". * Section 5.2, page 92, line 24: Remove the citation of "Bellucci, Morselli et al. 2004" (this paper does not investigate contrast sensitivity). * Section 5.2, page 92, line 29: Change author to "Caporossi et al. found a benefit [...]". * Section 5.2, page 92, line 32: Change author to "Tzelikis et al. recently reported [...]". * Section 5.3, page 103 f., Figures 5-30/5-31/5-32: Change legend of the x-axes of all diagrams from "Diameter [mm]" to "Distance from optical axis [mm]". * Section 5.3, page 105, Figure 5-33: Change figure legends to "pre-op measured", "post-op simulated (HBF)", "post-op simulated (VBF)" and "post-op measured" (in this order from left to right). * Section 5.3, page 105, line 21: Change text to "For 6 mm SA is decreased with homogeneous beam fluence [...]". * Section 5.3, page 106 f., Figures 5-34/5-35/5-37: Change "preop" to "pre-op" and "postop" to "post-op" where applicable. * References, page 120, number 115: Extend reference to "Hoffer, K. J. (1993). The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19(6): 700-12; Erratum (1994) 20(6): 677.". * Acknowledgements, page 137, line 8: Change name to "Dr. Katrin Petermeier". en
dc.description.abstract Das individuelle virtuelle Auge ist ein Computermodell eines menschlichen Auges zur Simulation der optischen Eigenschaften. Gängige Modellaugen wie das bekannte schematische Auge von Gullstrand basieren auf Daten von vielen Personen und zielen üblicherweise darauf ab, die Eigenschaften eines durchschnittlichen Auges zu repräsentieren. Im Gegensatz dazu basiert das individuelle virtuelle Auge auf Messwerten einer einzelnen Person. Entscheidend dabei sind geometrische Größen, insbesondere die axiale Länge und die Topographie der vorderen Hornhautoberfläche. Alle optischen Komponenten eines pseudophaken Auges – d.h. eines Auges mit einer künstlichen Linse – sind mit computertechnischen Methoden modelliert. Ein auf Spline-Interpolation basierendes Verfahren wurde entwickelt, um eine effiziente Integration von Messwerten einer Hornhauttopographie zu ermöglichen. Anhand dieses virtuellen Auges können unter Anwendung des Snell’schen Brechungsgesetzes und Ray-Tracing-Methoden geometrisch optische Eigenschaften, wie zum Beispiel die Wellenfrontaberration, simuliert werden. Darüber hinaus können mit computertechnischen Optimierungsmethoden auch optische Komponenten berechnet werden. Großer Wert wurde auf eine effiziente Implementierung der zeitkritischen numerischen Ray-Tracing- und Optimierungsmethoden gelegt, um eine kurze Berechnungszeit im Bereich von Sekunden zu erreichen. Dies führt zu klinischen Anwendungsgebieten in der Ophthalmologie, von denen einige in dieser Arbeit behandelt wurden. Dazu zählt die Intraokularlinsenberechnung für die Kataraktchirurgie, sowohl für normale als auch für schwierige Fälle wie nach refraktiver Chirurgie, bei denen bisherige Berechnungsmethoden unzulänglich sind. Ferner wurden auch individuell zugeschnittene asphärische Intraokularlinsen berechnet, und somit die Leistungsfähigkeit des Ray-Tracing-Verfahrens im Hinblick auf aufwendigere Linsengeometrien demonstriert. Als klinisch relevante Fragestellung wurde der optische Effekt einer Verdrehung oder Verkippung von Intraokularlinsen evaluiert. Darüber hinaus wurden Ablationsprofile untersucht, wie sie derzeit in der refraktiven kornealen Laserchirurgie eingesetzt werden. Eine zukünftige Erweiterungsmöglichkeit wäre die Einbeziehung eines Modells der natürlichen kristallinen Linse des Menschen, so dass auch phake Augen simuliert werden können. Auch konzentriert sich das virtuelle Auge bislang auf geometrisch optische Eigenschaften, könnte aber als Basis dienen für die Einbeziehung von physiologischen Eigenschaften von Netzhaut und Gehirn. de_DE
dc.language.iso en de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Auge , Optik , Ray tracing , Abbildungsfehler , Computersimulation , Optimierungsproblem , Kunststofflinse , Hornhautchirurgie de_DE
dc.subject.ddc 004 de_DE
dc.subject.other Pseudophakes Auge , Snell'sches Gesetz , Hornhauttopographie , Intraokularlinsenberechnung , Ablationsprofile de_DE
dc.subject.other Human optics , Computer simulation , Ray tracing , Intraocular lens calculation , Refractive surgery en
dc.title The individual virtual eye en
dc.title Das individuelle virtuelle Auge de_DE
dc.type PhDThesis de_DE
dc.date.updated 2009-08-06 de_DE
dcterms.dateAccepted 2008-02-13 de_DE
utue.publikation.fachbereich Informatik de_DE
utue.publikation.fakultaet 7 Mathematisch-Naturwissenschaftliche Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 3301 de_DE
thesis.grantor 17 Fakultät für Informations- und Kognitionswissenschaften de_DE

Dateien:

This item appears in the following Collection(s)

Show simple item record