dc.description.abstract |
Ziel:
Vergleich des intraokularen Drucks (IOD) gemessen mit dem iCare-rebound-tonometer (ICT) und dem Goldmann-Applanationstonometer (GAT) in einer Studienpopulation mit einem breiten IOD-Bereich unter der Berücksichtigung der zentralen Hornhautdicke (ZHD) in einem afrikanischen Entwicklungsland (Malawi).
Methoden:
In diesem Krankenhaus basiertem Survey wurden 150 Augen von 150 Patienten mit dem Ultraschall-Pachymeter gefolgt vom GAT und dem ICT untersucht und bezüglich ihres IOD in drei Gruppen eingeteilt: I: <16mmHg, II: 16-23mmHg, III: >23mmHg. Die Übereinstimmung zwischen den Tonometern wurde mit der Bland-Altman-Methode bestimmt. Für die Ermittlung der Abhängigkeit des ICT von der ZHD wurde die Differenz zwischen den korrigierten GAT-Werten und den ICT-Werten gegen die ZHD aufgetragen und aus der Steigungsgraden eine Korrekturformel für das ICT bestimmt.
Ergebnisse:
Die mittlere Differenz zwischen dem mit dem GAT und ICT gemessenen IOD betrug 0,84±2,63mmHg. Sie war in den drei Gruppen ähnlich (0,77-0,97mmHg) allerdings war die Standardabweichung in Gruppe III mit 4,04mmHg mehr als doppelt so groß wie in Gruppe I (1,98mmHg) und II (1,79mmHg). Die mittlere ZHD betrug 513,51±36,22µm. Für die Abhängigkeit des ICT von der ZHD wurde folgende Korrekturformel ermittelt: IODICT-Korrigiert= IODICT-unkorrigiert + ((ZHD-524) x (-0,0658))
Schlussfolgerung:
Die Übereinstimmung zwischen GAT und ICT war bei niedrigen IOD-Werten zufriedenstellend. In höheren IOD-Bereichen war das ICT für die Erfüllung der ISO-Norm zu ungenau. Insgesamt ist der Einsatz zum Screening des Glaukoms in Entwicklungsländern bei einem Mangel an anderen Geräten und gut ausgebildetem Personal trotzdem empfehlenswert. |
de_DE |
dc.description.abstract |
Purpose:
To compare the intraocular pressure (IOP) measured with the iCare rebound-tonometer and the Goldmann-applanation-tonometer over a wide IOP range and evaluate the influence of central corneal thickness in the natives of a developing country (Malawi).
Methodology:
In this hospital based survey 150 eyes of 150 Patients were devided into three groups concerning their IOP (I: <16mmHg, II: 16-23mmHg, III: >23mmHg) and underwent examination with ultrasound pachymetry followed by ICT and GAT. The agreement of the tonometers was assessed by the Bland-Altman-Method.
Results:
The mean difference between the IOD measured with the GAT and the ICT was 0.84±2.63mmHg. It was similar in all three groups (0.77-0.97) but the standard deviation in group III (4.04mmHg) was more than twice as big as in group I (1.98mmHg) and II (1.79mmHg). The mean CCT was 513.51±36.22µm. There was no association between the CCT and the GAT as well as the ICT.
Conclusion:
The agreement of the GAT and the ICT was good in lower IOP values but the ICT was not very accurate in group III. |
en |
dc.language.iso |
de |
de_DE |
dc.publisher |
Universität Tübingen |
de_DE |
dc.rights |
ubt-podok |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en |
en |
dc.subject.classification |
Glaukom , Entwicklungsländer |
de_DE |
dc.subject.ddc |
610 |
de_DE |
dc.subject.other |
iCare-Tonometer , Goldmann-Applanations-Tonometer , Hornhautdicke |
de_DE |
dc.subject.other |
Glaucoma , Developing countries , Goldmann-applanation-tonometer , Corneal thickness |
en |
dc.title |
Vergleich des iCARE-rebound-Tonometers mit dem Goldmann-Applanationstonometer unter Berücksichtigung der zentralen Hornhautdicke in einem afrikanischen Entwicklungsland (Malawi) |
de_DE |
dc.title |
Comparitive study of the iCare rebound.tonometer versus the Goldmann-applanation tonometer and the role of central corneal thickness in detecting high intraocular pressure in Malawi |
en |
dc.type |
PhDThesis |
de_DE |
dcterms.dateAccepted |
2010-10-29 |
de_DE |
utue.publikation.fachbereich |
Medizin |
de_DE |
utue.publikation.fakultaet |
4 Medizinische Fakultät |
de_DE |
dcterms.DCMIType |
Text |
de_DE |
utue.publikation.typ |
doctoralThesis |
de_DE |
utue.opus.id |
5632 |
de_DE |
thesis.grantor |
4 Medizinische Fakultät |
de_DE |