Real-time Feedback of B0 Shimming at Ultra High Field MRI

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Henning, Anke (Dr.)
dc.contributor.author Chang, Yu-Chun
dc.date.accessioned 2018-08-23T07:14:32Z
dc.date.available 2018-08-23T07:14:32Z
dc.date.issued 2018-07-30
dc.identifier.other 510667813 de_DE
dc.identifier.uri http://hdl.handle.net/10900/83819
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-dspace-838193 de_DE
dc.identifier.uri http://dx.doi.org/10.15496/publikation-25209
dc.description.abstract Magnetic resonance imaging(MRI) is moving towards higher and higher field strengths. After 1.5T MRI scanners became commonplace, 3T scanners were introduced and once 3T scanners became commonplace, ultra high field (UHF) scanners were introduced. UHF scanners typically refer to scanners with a field strength of 7T or higher. The number of sites that utilise UHF scanners is slowly growing and the first 7T MRI scanners were recently CE certified for clinical use. Although UHF scanners have the benefit of higher signal-to-noise ratio (SNR), they come with their own challenges. One of the many challenges is the problem of inhomogeneity of the main static magnetic field(B0 field). This thesis addresses multiple aspects associated with the problem of B0 inhomogeneity. The process of homogenising the field is called "shimming". The focus of this thesis is on active shimming where extra shim coils drive DC currents to generate extra magnetic fields superimposed on the main magnetic field to correct for inhomogeneities. In particular, we looked at the following issues: algorithms for calculating optimal shim currents; global static shimming using very high order/degree spherical harmonic-based (VHOS) coils; dynamic slice-wise shimming using VHOS coils compared to a localised multi-coil array shim system; B0 field monitoring using an NMR field camera; characterisation of the shim system using a field camera; and designing a controller based on the shim system model for real-time feedback. en
dc.language.iso en de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Kernspintomografie de_DE
dc.subject.ddc 500 de_DE
dc.subject.other B0 Shimming en
dc.title Real-time Feedback of B0 Shimming at Ultra High Field MRI en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2018-07-05
utue.publikation.fachbereich Biologie de_DE
utue.publikation.fakultaet 7 Mathematisch-Naturwissenschaftliche Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige