Entwicklung und Validierung eines Testsystems zur Evaluierung der gerinnungsaktivierenden Potenz von Bauchtüchern

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Wendel, Hans-Peter (Prof. Dr.)
dc.contributor.author Nathan, Tanja Olga
dc.date.accessioned 2015-11-26T08:26:00Z
dc.date.available 2015-11-26T08:26:00Z
dc.date.issued 2015
dc.identifier.other 452376297 de_DE
dc.identifier.uri http://hdl.handle.net/10900/66662
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-dspace-666622 de_DE
dc.identifier.uri http://dx.doi.org/10.15496/publikation-8082
dc.description.abstract The background of this thesis are clotting problems caused by green abdominal swabs during cardiac surgery supported by heart lung machines. Amongst all surgical departments cardiac surgery poses an exception regarding hyper-coagulating abdominal swabs, since patients are pre-operatively medicated with heparin while surgery is performed without the use of a cell saver. Thus excessive blood clotting resulting from faulty abdominal swabs leads to thrombo-embolic complications. The goal was the development and validation of an in-vitro clotting test to evaluate the blood coagulation of abdominal swabs with hyper-coagulant potency. During the tests samples of various batches of abdominal swabs with heparinized human blood from 100 donors were incubated on a shaking plate for 30 minutes at 37°C and then examined micro- and macroscopically for blood clots and evaluated on the basis of a dichotomized evaluation system. Additionally SEM (scanning electron microscopy) images were made and the ACT (activated clotting times) measured. The goal of this prospective study was met. It can be assumed that with the newly developed test system eleven donors are needed to detect a swab with hyper-coagulating potential with a probability of 95% in 25% of donors. This test provides a safe preclinical testing method to detect abdominal swabs with hyper-coagulant potential. Consequently, it makes an important contribution in the future to minimize the risk of thrombo-embolic complications during cardiac surgery supported by heart lung machines. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podno de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=en en
dc.subject.classification Bauchtuch de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Bauchtücher de_DE
dc.subject.other Abdominal swabs en
dc.title Entwicklung und Validierung eines Testsystems zur Evaluierung der gerinnungsaktivierenden Potenz von Bauchtüchern de_DE
dc.type PhDThesis de_DE
dcterms.dateAccepted 2015-06-12
utue.publikation.fachbereich Medizinische Fakultät de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige