Monte-Carlo Simulation der Dosimetrie kleiner Felder in der Strahlentherapie mit hochenergetischen Photonen

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Nüsslin, Fridtjof de_DE
dc.contributor.author Dohm, Oliver Steffen de_DE
dc.date.accessioned 2005-04-04 de_DE
dc.date.accessioned 2014-03-18T10:14:00Z
dc.date.available 2005-04-04 de_DE
dc.date.available 2014-03-18T10:14:00Z
dc.date.issued 2005 de_DE
dc.identifier.other 117196975 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-16514 de_DE
dc.identifier.uri http://hdl.handle.net/10900/48726
dc.description.abstract Moderne Bestrahlungsplanungssysteme bieten die Möglichkeit, einen Monte-Carlo (MC) Dosisberechnungsalgorithmus zu verwenden. Dieser hat den Vorteil, dass die Berechnung der Patientendosis auch in nicht homogenen Bereichen, etwa in der Lunge, sehr genau durchgeführt wird. Um aber die gewünschte Genauigkeit von besser als 2% zu erreichen, wird nicht nur ein präziser Algorithmus, sondern auch ein genaues Modell des Beschleunigerkopfes benötigt. In der vorliegenden Arbeit wurde ein solches Modell eines Beschleunigerkopfes für den MC Code "BEAMnrc" entwickelt. Das Modell wurde anhand von Messungen in einem Wasserphantom so angepasst, dass eine Übereinstimmung zu den Messungen von besser als 1% auf der Zentralachse und besser als 2% im übrigen Feld erreicht wurde. Außerdem wurde ein Modell einer Ionisationskammer verwendet, um damit kammerabhängige Faktoren für die Dosimetrie kleiner Felder zu ermitteln. Mit Hilfe der in der Arbeit entwickelten detaillierten Modells des Beschleunigerkopfes wurde dann die Frage untersucht, ob ein wesentlich schnelleres analytisches Kopfmodell für den "XVMC" MC Code die selbe Genauigkeit wie das detaillierte Modell erreichen kann. Diese Untersuchung wurde sowohl auf der Zentralachse, wie auch auf achsfernen Punkten vogenommen. Dabei wurde sowohl die relative Dosisverteilung, wie auch die absolute Dosis, verglichen. Insgesamt konnte gezeigt werden, dass die Genauigkeit des detaillierten und des analytischen Kopfmodells für die Berechnung der Patientendosis gleichwertig ist. Somit ist es möglich, im Rahmen des Tübinger HYPERION Projektes eine Monte-Carlo basierte Bestrahlungsplanung durchzuführen. de_DE
dc.description.abstract Modern treatment planning systems have the possibility to use Monte-Carlo (MC) based dose calculating algorithms. The latter have the advantage that the patient dose calculation can be done very accurately also in non-homogenous tissues, like lung. To reach the desired accuracy of better than 2% not only a precise algorithm, but also an accurate model of the treatment head is needed. Within this thesis such a model of a treatment head was developed for the MC algorithm "BEAMnrc". The model was commissioned with measurements in water until the agreement to the measurements was better than 1% on the central axis and better than 2% everywhere else. Also a model of an ionization chamber was used to derive chamber dependent factors for small field dosimetry. With the treatment head model developed in this thesis the question was investigated, if a substantial faster analytical head model for the "XVMC" Code will reach the same accuracy as the detailed model. This investigation was made on the central axis, as well as for off-axis positions. Not only relative dose distributions, but also absolute doses, were compared at these positions. Altogether it could be shown that the accuracy of the detailed and the analytical treatment head model is of equal value for patient dose computation. Because of this it is possible to do Monte-Carlo based treatment planning on a routinely basis within the Tübingen HYPERION project. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Dosimetrie , Monte-Carlo-Simulation , Linearbeschleuniger de_DE
dc.subject.ddc 530 de_DE
dc.subject.other kleine Felder , Beschleunigerkopf de_DE
dc.subject.other Monte-Carlo-simulation , dosimetry , small fields , treatment head en
dc.title Monte-Carlo Simulation der Dosimetrie kleiner Felder in der Strahlentherapie mit hochenergetischen Photonen de_DE
dc.title Monte-Carlo simulation of small field dosimetry in radiotherapy with high-energy photons en
dc.type PhDThesis de_DE
dc.date.updated 2005-04-04 de_DE
dcterms.dateAccepted 2004-12-15 de_DE
utue.publikation.fachbereich Sonstige - Mathematik und Physik de_DE
utue.publikation.fakultaet 7 Mathematisch-Naturwissenschaftliche Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 1651 de_DE
thesis.grantor 12/13 Fakultät für Mathematik und Physik de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige