dc.contributor.advisor |
Bauer, H. |
de_DE |
dc.contributor.author |
Niebauer, Holger |
de_DE |
dc.date.accessioned |
2002-03-21 |
de_DE |
dc.date.accessioned |
2014-03-18T10:10:00Z |
|
dc.date.available |
2002-03-21 |
de_DE |
dc.date.available |
2014-03-18T10:10:00Z |
|
dc.date.issued |
2002 |
de_DE |
dc.identifier.other |
099092484 |
de_DE |
dc.identifier.uri |
http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-4765 |
de_DE |
dc.identifier.uri |
http://hdl.handle.net/10900/48344 |
|
dc.description.abstract |
Die Entwicklung eines „echten“ on-line Mikro-Titrationssystems mit neuartigem Titrationsprinzip
sowie eines Nano-Injektions- und Flusssteuerungssystems auf Basis ultrahochauflösender
Linearaktoren für die Kapillarelektrophorese werden beschrieben. Bei
dem auf einem Fließinjektionsanalyse-System basierenden on-line-Autotitrator werden
alle herkömmlichen, teuren Dosierelemente durch ein simples computergesteuertes Mikrodreiwegeventil
und eine Mikrodosierpumpe ersetzt, wodurch sich die Kosten auf ca.
10 der heute verfügbaren Autotitratoren senken lassen. Das traditionelle Prinzip der
schrittweisen Zugabe von Titrant zu einer vorgelegten Menge an Probe wird in ein einfaches
alternatives Ansteuern von Proben- und Reagenzstrom abgeändert. Die vollständige
Übertragbarkeit von DIN-Methoden auf das neuartige Mikro-Titrationssystem wird aufgezeigt.
Die Flusssteuerung für die Kapillarelektrophorese ermöglicht es, Probenvolumina im
(Sub-)Nanoliterbereich reproduzierbar zu injizieren und an jede beliebige Stelle der Kapillare
mit Picoliterauflösung zu positionieren. Mit diesem Prinzip wird die Simultanbestimmung
auch der „schnellsten“ Kationen und Anionen in nur einem Lauf innerhalb weniger
Minuten realisierbar. Die Flexibilität ist im Vergleich zu herkömmlichen Systemen
deutlich größer und dürfte neue Aspekte in der Ionenanalytik eröffnen. |
de_DE |
dc.description.abstract |
A ”real” on line micro titration system based on a new titration principle as well as a
nano injection and flow control system for capillary electrophoresis based on ultra-high
resolution linear actuators are developed. The new on line auto titrator is realized with a
modified flow injection analysis system. All conventional and expensive techniques for
dosing are substituted by a simple computer controlled micro three way valve and a micro
pump. The costs compared to commercially available auto titrators are decreased by
approximately 90 The classic titration principle of step by step addition of titrant to an
exactly known amount of sample is replaced by a simple switching frequency in between
sample and reagent stream. Methods according to DIN can be easily transferred to the
new micro titration system.
The new flow control system for capillary electrophoresis allows to inject sample amounts
of nano and pico liters only with high accuracy. Furthermore it is possible to correctly
position the sample plug within the capillary with a resolution in the range of few pico
liters. With this technique the simultaneous determination of even the ”fastest” cations
and anions within one run and only a few minutes can be realized. The flexibility in
comparison to conventional systems is much higher. This nano flow control system might
open new aspects in ion analysis. |
en |
dc.language.iso |
de |
de_DE |
dc.publisher |
Universität Tübingen |
de_DE |
dc.rights |
ubt-podok |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en |
en |
dc.subject.classification |
Elektrophorese , Titration |
de_DE |
dc.subject.ddc |
540 |
de_DE |
dc.subject.other |
Elektrophorese , Titration |
de_DE |
dc.subject.other |
Chemical micro systems , Capillary electrophoresis , On line micro titration , Nano positioning , Simultaneous determination of cat- and anions |
en |
dc.title |
Neuartige analytische Mikrotechniken für die Biochemie und die Umweltüberwachung |
de_DE |
dc.title |
New analytical micro techniques for biochemistry and environmental monitoring |
en |
dc.type |
PhDThesis |
de_DE |
dc.date.updated |
1970-01-01 |
de_DE |
dcterms.dateAccepted |
2002-03-15 |
de_DE |
utue.publikation.fachbereich |
Sonstige - Chemie und Pharmazie |
de_DE |
utue.publikation.fakultaet |
7 Mathematisch-Naturwissenschaftliche Fakultät |
de_DE |
dcterms.DCMIType |
Text |
de_DE |
utue.publikation.typ |
doctoralThesis |
de_DE |
utue.opus.id |
476 |
de_DE |
thesis.grantor |
14 Fakultät für Chemie und Pharmazie |
de_DE |