Dynamisch-optische Oberflächenvermessung des plantaren Fußes

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Wank, Veit (Prof. Dr.) de_DE
dc.contributor.author Schmeltzpfenning, Timo de_DE
dc.date.accessioned 2012-02-17 de_DE
dc.date.accessioned 2014-03-18T10:03:51Z
dc.date.available 2012-02-17 de_DE
dc.date.available 2014-03-18T10:03:51Z
dc.date.issued 2011 de_DE
dc.identifier.other 359298893 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-60467 de_DE
dc.identifier.uri http://hdl.handle.net/10900/47901
dc.description.abstract Dynamisch-optische Oberflächenvermessung des plantaren Fußes Inhalt und Vorgehensweise Die Entwicklung eines zeitauflösenden dreidimensionalen Fußscanners unter Verwendung einer dynamisch-optischen Oberflächenvermessung stellt die primäre Zielsetzung dar. Dieses System wurde anschließend genutzt, um erste Erkenntnisse zur dynamischen Fußformveränderung über den Abrollvorgang zu gewinnen. Die Relevanz der Formveränderung, z.B. für die industrielle Schuhfertigung, wird in der Arbeit abschließend diskutiert. Hintergrund der Arbeit Bisherige kommerziell erhältliche Messsysteme sind auf die Erhebung der 3D-Fußmaße in der statischen Situation beschränkt. Es ist jedoch anzunehmen, dass die statische Fußform sich unter wechselnden Belastungssituationen, wie sie in der Dynamik vorkommen, entscheidend verändert. Die Anpassung der menschlichen Fußstruktur an die dynamischen Gegebenheiten ist bisher auf Grund fehlender Messtechnik nur unzureichend erforscht und berücksichtigt worden. Basierend auf diesen Defiziten, wurde das Ziel verfolgt, eine Messtechnik zu entwi-ckeln, die eine zuverlässige Erfassung der dreidimensionalen Oberflächeninformation der menschlichen Fußform während des Gehens ermöglicht. Mit Hilfe der Messtechnik wurden anschließend die Fußformveränderungen innerhalb des Abrollvorgangs sowie die Unterschiede zwischen der statischen und der dynamischen Fußform quantifiziert. Methode Es wurde ein plantares System, bestehend aus drei Scanner-Einheiten, zur dreidi-mensionalen Erfassung der Fußsohle entwickelt. Das zugrunde liegende Messprinzip wird als phasenkodierte Triangulation mit einem flächenhaften Projektionsverfahren bezeichnet. Der Vorteil dieser Technologie besteht in der zeitlich parallelen Erfassung eines Raumwinkels, wodurch die Vermessung ganzer Oberflächen innerhalb kürzester Zeit ermöglicht wird. Unter Verwendung von hochfrequenten Kamera- und Projektor-Einheiten wurde eine Messfrequenz von 41 Hz erreicht. Die drei Hauptgü-tekriterien der Messtechnik (Validität, Objektivität, Reliabilität) sind an einer Stichpro-be von 109 Personen untersucht worden. Im Rahmen einer klinischen Studie konnten die Füße von insgesamt 129 Probanden dynamisch bei einer standardisierten Geschwindigkeit von 4.5 km/h erfasst werden. Die Analyse der Daten schließt die Dynamik, die Statik, mögliche Einflussfaktoren sowie Modellgenerierungen zur Erklärung der dynamischen Veränderungen mit ein. Ergebnisse Die Ergebnisse der Testgütekriterien deuten darauf hin, dass bei ausreichender örtli-cher Auflösung des Systems die Zuverlässigkeit der Datenerhebung vorwiegend von zwei Faktoren abhängig ist – dem zu erhebenden Fußmaß sowie der Objektge-schwindigkeit. Gruppenmittelwerte zeigen weder systematische Abweichungen (Bias) noch eine Heteroskedastizität in den Datenwolken. Während der Vergleich der statischen zu den dynamischen Fußmaßen lediglich ge-ringe Differenzen nachwies, zeigen die dynamischen Messungen innerhalb des Ab-rollvorgangs signifikante Veränderungen in den Längen-, Breiten- und Höhenmaßen des Fußes. Die Ergebnisse zeigen eine große individuelle Variabilität zwischen den Probanden, die sich nicht vollständig mit den untersuchten Einflussfaktoren (Alter, Geschlecht, Gewicht) oder den generierten Modellen erklären lassen. Diskussion Die Testgütekriterien weisen auf eine zuverlässige Darstellung von Gruppendifferen-zen für alle erhobenen dynamischen Fußmaße hin. Eine valide Beurteilung der Fußformveränderungen bei Einzelpersonen ist mit den realisierten technischen Möglichkeiten jedoch nicht für jede Standphase gewährleistet. Die Veränderungen der Fußform durch die variierenden Belastungssituationen über den Abrollvorgang zeigen im Allgemeinen ein geringeres Ausmaß als hypothetisch angenommen. Dennoch verdeutlichen die klinischen Ergebnisse der dynamisch-optischen Oberflächenvermessung des Fußes, dass der entwickelte dynamische Fußscanner ergänzende Informationen zur Gestaltung von Leisten, Einlagen und Schuhen liefern kann. de_DE
dc.description.abstract Dynamic-optical surface measurement of the plantar foot Aim of the thesis The overall aims of the thesis were the development of a 3D-footscanner using a dy-namic-optical surface measurement technique and to quantify the changes in foot shape during walking. Introduction Even though there are several kinds of foot scanners providing high accuracy, the analysis of the human foot shape while walking has not yet been realised. Up to now, most investigations have been performed in static, semi-weight-bearing conditions. However, considerable differences between static and dynamic conditions as well as in loaded and unloaded foot structure can be expected due to changing ground reac-tion forces and biomechanical functions of the foot during stancephase of walking. Therefore, the aim of this project was to develop a 3D-scanner-system, combining high resolution with short recording time, to capture the dynamic foot shape during the roll over process (ROP) of walking. This measurement device was used to gain first results on the dynamic changes of the foot dimensions during walking. Method Deriving from an elaborated analysis of potentially suitable measurement techniques for dynamic three-dimensional measurements of the human foot, a system based on LED surface projection was realized. Three synchronized scanner units, each con-sisting of one CCD-camera and one projector (Vialux GmbH), were used to capture the plantar foot shape during the ROP. The measurement system uses the structured light method, where a series of fringes is used to provide 3D-shape information. The measurement devices were placed below a safety glass platform (60 x 40 cm) which was integrated into a walkway of 460 cm length and 80 cm height. With this setup, the foot could be captured at a frame rate of 41 fps under natural walking conditions. The main quality criteria of the new dynamic foot scanner (validity, objectivity, reliabil-ity) were examined by using a sample size of 109 subjects. A clinical study including 129 volunteers was carried out to analyze the foot deformations during walking. All subjects walked barefoot at a predefined speed of 4.5 km/h ± 5%, which was con-trolled using photo cells. After an adequate adaptation phase, they performed three dynamic and two static trials. The static measurements were taken in a semi-weight-bearing situation with the bodyweight evenly distributed on both feet. Using intersection planes, the data were evaluated manually (Geomagic Qualify 8). The analysis considered differences during the dynamic situation, differences be-tween dynamic and static conditions as well as influencing factors such as age, body weight and gender. Finally, a stepwise regression analysis was used to explain the dynamic behavior of the human foot. Results The analysis of the main quality criteria’s points out two factors which primarily affect the reliability of the dynamic foot scanner, the object velocity, and the measurement value itself, whereas the spatial resolution of the system is sufficient. Arch measure-ment values have lowest and width measures the highest reliability. Neither do all group values show a systematic error nor a heteroscedasticity in the point clouds. The findings of the clinical study indicate that the differences between static and dy-namic foot measurement values are lower than hypothetically assumed, whereas measurement within different dynamic stance phases show significant changes in foot length, width and height. Results show high individual variations, which cannot be fully explained by considering influencing factors or by calculating the stepwise regression model. Discussion The measurement device implemented in this thesis provides highly reliable data for group differences for all investigated dynamic foot measurements. However, a valid evaluation of foot form deformities for single subjects cannot be guaranteed for all stance phases during ROP of walking. Overall, the changes of foot dimensions due to different loading situations during the ground contact of walking are lower than expected. Nevertheless, the results of the clinical study of the dynamic optical surface measurement device reveal that the dy-namic foot scanner can provide additional information for last, insole, and shoe con-struction. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Scanning , Fußdeformität , Biomechanik , Optische Messtechnik de_DE
dc.subject.ddc 796 de_DE
dc.subject.other 3D-dynamisch , Dynamische Fußformveränderungen de_DE
dc.subject.other Scanning , Foot deformation , Surface measurement , Plantar foot , Dynamic en
dc.title Dynamisch-optische Oberflächenvermessung des plantaren Fußes de_DE
dc.title Dynamic-optical surface measurement of the plantar foot en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2011-12-16 de_DE
utue.publikation.fachbereich Sportwissenschaft de_DE
utue.publikation.fakultaet 6 Wirtschafts- und Sozialwissenschaftliche Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 6046 de_DE
thesis.grantor 6 Wirtschafts- und Sozialwissenschaftliche Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige