dc.contributor.advisor |
Möhrle, Matthias (Prof. Dr.) |
de_DE |
dc.contributor.author |
Ziefle, Sarah |
de_DE |
dc.date.accessioned |
2013-06-20 |
de_DE |
dc.date.accessioned |
2014-03-18T09:46:27Z |
|
dc.date.available |
2013-06-20 |
de_DE |
dc.date.available |
2014-03-18T09:46:27Z |
|
dc.date.issued |
2013 |
de_DE |
dc.identifier.other |
383793300 |
de_DE |
dc.identifier.uri |
http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-68813 |
de_DE |
dc.identifier.uri |
http://hdl.handle.net/10900/46085 |
|
dc.description.abstract |
Die Zielsetzung dieser Promotion ist es ex vivo confocal laser scanning microscopy (CLSM), eine Methode zur schnellen Bilderhebung ohne lange Aufarbeitung des Gewebes, mit 3-dimensionaler Histologie (3D-Histologie) Bilderhebung, was der Standart für die Gewebeaufarbeitung ist, zu vergleichen.
Für diese Studie wurden zweiundsiebzig fortlaufend chirurgisch entfernte Basalzellkarzinome (BZK) untersucht. Für die 3D-Histologie Bilderhebung wurde die Paraffin Technik benutzt. Um die einzelnen BZKs zu beurteilen wurden sie entweder als Tübinger Torte, Muffin oder Brotlaib präpariert.
Die einzelnen Proben wurden mit Essigsäure behandelt und anschließend mit toluidinblau gefärbt um dann mit dem CLSM zu beurteilt werden. Nachdem das entsprechende Bild mit dem CLSM gemacht worden ist wurden die Proben routinegemäß mit hämatoxilin-eosin gefärbt und mit der Standard Paraffin 3D Methode verarbeitet.
Für die CLSM Bildgebung wurde ein modifizierte Version des kommerziell erhältlichen CLSM (VivaScope2500; Lucid Inc, Rochester, New York) benutzt. Durch die kurze Einscannzeit konnte der entsprechende Operateur umgehend nach der Operation die CLSM Bilder seiner OP bewerten.
Es wurden 312 CLSM Bilder erzeugt, davon waren 73 Mittelschnitte, 196 Ränder, 23 Muffins und 20 Brotlaibe, von insgesamt 72 entnommenen BZKs. Die Mittelschnitte erreichten eine Sensitivität von 94%, Ränder 73,7%, Muffins und Brotlaib jeweils 80%.
Mit dem technisch verbesserten Vivascope2500, konnten alle 312 CLSM Bilder direkt auf dem CLSM Bildschirm angeschaut und bewertet werden. Daher war es zum ersten Mal möglich diese Methode als einen Standard Prozess in den OP Alltag zu integrieren. Die Erfassung der Bilder konnte in weniger als 3 Minuten erreicht werden.
Leider konnte die erwünschte BZK Trefferquote, die nötig wäre um diesen Prozess auch zukünftig als Standard einzusetzen, nicht erreicht werden. Da er die Auswertung zwischen oder während den OPs gemacht wurde hängt einer der Gründe sicherlich mit den Faktoren Stress, Zeit und Müdigkeit des jeweiligen Arztes/Operateurs zusammen. Nach
und nach konnte auch eine Verbesserung der Bearbeitung von den jeweiligen Proben beobachtet werden, was auch mit ein Grund für die Variabilität zwischen den verschiedenen Auswerten sein kann.
Wie dem auch sei, für die Nutzung der CLSM Bilder muss eine höhere Sensitivität und Spezifität erreicht werden. Für weitere Studien könnte ein spezifischer fluoreszent Farbstoff, um BZK Zellen spezifisch anzufärben, in Kombination mit dem CLSM benutzt werden. Das wäre eine Revolution in der micrographic surgery.
Bis jetzt hat CLSM leider noch nicht das optimale Ziel erreicht, es kann aber für die Zukunft eine enorm zeitsparend und billigere Methode sein als die bis jetzt verwendete 3D- Paraffin Histologie. |
de_DE |
dc.description.abstract |
The goal of this Promotion is to compare ex vivo confocal laser scanning microscopy (CLSM), which offers rapid images without the need for tissue processing, vs 3-dimensional histologic imaging, the criterion standard treatment for basal cell carcinomas in high-risk areas of the face. Furthermore the aim is to evaluate if the use of ex vivo CLSM is viable for the diary clinical life.
For the study seventy-two consecutive surgically removed BCCs were examined. For 3-dimensional histologic slides, the paraffin technique was used. The tumor specimens were further dissected using the following techniques: Tübinger torte, muffin, and “bread loaf” (using 1-mm step sections).
The specimens were incubated in acetic acid and stained with toluidine blue before CLSM imaging. After imaging, the specimens were placed in a routine cassette, and tissue was prepared using the standard paraffin method with hematoxylin-eosin staining.
For the CLSM imaging a modified version of a commercially available confocal laser scanning microscope was used; this version was designed for imaging ex vivo excised fresh tissue. Immediately after surgery, all imaged confocal mosaics of an excised tumor specimen were evaluated by the attending surgeon.
A total of 312 images, including 73 midsections, 196 lateral margins, 23 muffins, and 20 bread loaf sections, were obtained using CLSM from 72 surgically removed BCCs. The sensitivity of CLSM reached 94.0% in midsections, 73.7% in lateral margins, 80.0% in muffins, and 80.0% in bread loaf sections.
With the technical improved VivaScope 2500, images could be observed directly on the display of the VivaScope. So for the first time it was possible to integrate the CLSM as a standard procedure in surgical daily routine.
A complete mosaic of the size of 13 mm x 11 mm could be obtained in less then three minutes, what never before has been reached.
Unfortunately the BCC identification rate on the scans of micrographic surgery specimens did not reach the desired hit rate. One of the reasons could be the immediacy of evaluations during or between surgical procedures, factors such as time pressure, stress, or fatigue could have influenced the results. There was also a continuous improvement in handling and fixing the fresh tissue. This factor might have influenced the interobserver variability.
However, for the use of BCC identification on images of micrographic surgery (CLSM) specimens there must be a higher sensitivity and specificity.
For further investigations specific fluorescence could be used in combination with the microscope used herein, offering fast imaging and correct interpretation directly in the operating theater. This would represent a revolution in micrographic surgery.
In conclusion, CLSM lacks high sensitivity to detect small tumor strands of BCCs. Training surgeons to read CLSM images is essential. For micrographic surgery, CLSM may represent a timesaving and less expensive alternative to cryostat histopathologic examination. |
en |
dc.language.iso |
de |
de_DE |
dc.publisher |
Universität Tübingen |
de_DE |
dc.rights |
ubt-podno |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=de |
de_DE |
dc.rights.uri |
http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=en |
en |
dc.subject.classification |
Histologie , Basaliom |
de_DE |
dc.subject.ddc |
610 |
de_DE |
dc.subject.other |
Konfokale Laser Scanning Mikroskopie , Basalzellkarzinom |
de_DE |
dc.subject.other |
Confocal Laser Scanning Microscopy , Basal cell carcinoma |
en |
dc.title |
Konfokale Laser Scanning Mikroskopie vs 3D- Histologie in Paraffinschnitten in der mikroskopisch kontrollierten Chirurgie von Basalzellkarzinomen |
de_DE |
dc.title |
Confocal Laser Scanning Microscopy vs 3-Dimensional Histologic Imaging in Basal Cell Carcinoma |
en |
dc.type |
PhDThesis |
de_DE |
dcterms.dateAccepted |
2013-05-15 |
de_DE |
utue.publikation.fachbereich |
Medizin |
de_DE |
utue.publikation.fakultaet |
4 Medizinische Fakultät |
de_DE |
dcterms.DCMIType |
Text |
de_DE |
utue.publikation.typ |
doctoralThesis |
de_DE |
utue.opus.id |
6881 |
de_DE |
thesis.grantor |
4 Medizinische Fakultät |
de_DE |