Untersuchung des Kontrastsehens: Welches Verfahren ist am besten geeignet?

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Wilhelm, Helmut (Prof. Dr. ) de_DE
dc.contributor.author Naycheva, Lubka Georgieva de_DE
dc.date.accessioned 2012-11-12 de_DE
dc.date.accessioned 2014-03-18T09:45:51Z
dc.date.available 2012-11-12 de_DE
dc.date.available 2014-03-18T09:45:51Z
dc.date.issued 2012 de_DE
dc.identifier.other 373532563 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-65084 de_DE
dc.identifier.uri http://hdl.handle.net/10900/46023
dc.description.abstract Ziel: Das Ziel dieser Studie war es, vier Tests zur Prüfung des Kontrastsehens untereinander zu vergleichen. Methoden: 114 Probanden, unterteilt in 3 Gruppen (Gruppe I: 41 junge, gesunde Probanden (22-32 Jahre alt) mit Visus >= 1,0; Gruppe II: 40 ältere Probanden (50-66 Jahre alt) mit klaren brechenden Medien und Visus >= 0,8; Gruppe III: 33 Probanden (62-84 Jahre alt) mit Katarakt >= NO3/NC3/C3 und < P3 nach Lens Opacities Classification System III und Visus >= 0,5) wurden monokular und binokular mit Pelli-Robson Contrast Sensitivity Chart, Mesoptometer I (bei Umfeldleuchtdichte von 0,1 cd/m² und 0,032 cd/ m²), Freiburg Visual Acuity and Contrast Test (FrACT) und Rodatest 302 (bei Umfeldleuchtdichte von 10 cd/m² und 300 cd/m²) untersucht. Ergebnisse: Bei allen Tests waren die Ergebnisse der Gruppe I am besten, folgend von Gruppe II und dann Gruppe III. Es zeigten sich signifikante Unterschiede (ANOVA, Tukey-Kramer, p < 0,05) bei allen getesteten Verfahren, mit Ausnahme des Mesoptometer I bei Umfeldleuchtdichte von 0,1 cd/m², getestet binokular Gruppe I vs. Gruppe II (p = 0,15). Am empfindlichsten erwies sich das Mesoptometer I bei Umfeldleuchtdichte von 0,032 cd/m² (F=222,5). Die beste Differenzierung zwischen Gesunden und Probanden mit herabgesetztem Kontrastsehen erfolgte durch Mesoptometer I bei Umfeldleuchtdichte von 0,032 cd/m² (Area Under the Curve, AUC = 0,98). Am schlechtesten schnitt die Pelli-Robson Tafel ab (AUC = 0,87), die anderen Verfahren lagen mit AUC von 0,88 bis 0,93 dazwischen. Die beste rechts-links Korrelation (nach Pearson) zeigte Mesoptometer I bei Umfeldleuchtdichte von 0,1cd/m² mit 0,81. Schlussfolgerung: Alle vier Tests konnten die gestellten Anforderungen zufriedenstellend erfüllen. Aufgrund der einfacheren und schnelleren Durchführbarkeit sind Tests unter photopischen Bedingungen in der Praxis jedoch zu bevorzugen. Das historische Mesoptometer I kann als Goldstandard dienen. de_DE
dc.description.abstract Purpose: The purpose of this study was to compare four tests for measurement of contrast sensitivity. Methods: 114 volunteers were enrolled in the study and were divided into three groups: - group I: 41 young, healthy subjects (22-32 years) with visual acuity (VA) >= 1.0; - group II: 40 elderly subjects (50-66 years) with clear ocular media and VA >= 0.8; - group III: 33 subjects (62-84 years) with cataract >= NO3/NC3/C3 and < P3 according to the Lens Opacities Classification System III (LOCS III) and VA >= 0.5. All subjects were tested monocularly and binocularly with Pelli-Robson Contrast Sensitivity Chart, Mesoptometer I (with 0.1 cd/m² and 0.032 cd/ m² background luminance), Freiburg Visual Acuity and Contrast Test (FrACT) and Rodatest 302 (with 10 cd/m² and 300 cd/m² background luminance). Results: Group I yielded the best results in all tests, followed by groups II and III. Significant differences (ANOVA, Tukey-Kramer, p < 0.05) were found in all tests except fort he Mesoptometer I with 0.1 cd/m² background luminance when testing group I vs. group II (p = 0.15). Mesoptometer I with 0.032 cd/m² background luminance proved to be most sensitive (F=222.5). Mesoptometer I with 0.032 cd/m² background luminance also showed the highest discriminative ability between healthy and subjects with reduced contrast sensitivity (Area Under the Curve, AUC = 0.98). Pelli-Robson Chart had the poorest discriminative ability (AUC = 0.87), while the other tests yielded intermediate AUC between 0.88 and 0.93. The best correlation between left and right eye (0.81, after Pearson) was achieved with Mesoptometer I with 0.1 cd/m² background luminance. Conclusion: All four tests sufficiently met our requirements. Owing to the simplicity and faster handling tests under photopic conditions should be preferred. The historic Mesoptometer I can serve as a gold standard. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Visueller Kontrast de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Kontrastsehen , Dämmerungssehen , Pelli-Robson-Test , Rodatest , Mesoptometer de_DE
dc.subject.other Contrast sensitivity , Pelli-Robson Contrast Sensitivity Chart , Freiburg Visual Acuity and Contrast Test, Rodatest en
dc.title Untersuchung des Kontrastsehens: Welches Verfahren ist am besten geeignet? de_DE
dc.title Measurement of Contrast Sensitivity: Which Test is Most Suitable? en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2008-04-29 de_DE
utue.publikation.fachbereich Medizin de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 6508 de_DE
thesis.grantor 4 Medizinische Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige