Kraftaufnahme des vorderen Kreuzbands in einer gewichtssimulierten Flexion unter anteriorer Translations- und interner Rotationsbelastung der Tibia. Eine neue Methode zur Quantifizierung von dynamischen Belastungen

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Wülker, N. (Prof. Dr.) de_DE
dc.contributor.author Bauer, Theodor Steffen de_DE
dc.date.accessioned 2011-05-27 de_DE
dc.date.accessioned 2014-03-18T09:44:23Z
dc.date.available 2011-05-27 de_DE
dc.date.available 2014-03-18T09:44:23Z
dc.date.issued 2011 de_DE
dc.identifier.other 345108647 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-56363 de_DE
dc.identifier.uri http://hdl.handle.net/10900/45841
dc.description.abstract Die vorliegende Studie untersucht die in vitro Kraftverläufe und beleuchtet den Effekt von externen tibialen Belastungszuständen auf den Kraftverlauf im vorderen Kreuzband während einer simulierten Knieflexion mit Körpergewichtsbelastung. Neun humane Kadaverknie wurden an einen dynamischen Kniesimulator angebracht, um gewichtbelastete Knieflexionen mit einer Bodenreaktionskraft von 100 N zu simulieren. Gleichzeitig kam ein Roboter/ UFS Messungssystem zum Einsatz, welches im Kniekinemator dazu benutzt wurde externe tibiale Belastungszustände während der Bewegung zu simulieren. Drei externe tibiale Belastungszustände mit 100 N Gewichtssimulation (“BW only 100 N“), 50 N anteriore Translation (“ATF“) und 5 Nm internes tibiales Drehmoment (“ITT“) wurden simuliert. Die tibiale und femorale Kinematik wurde mit Hilfe eines ultraschallgesteuerten Bewegungsmesssystem gemessen. Diese Bewegungspfade wurden dann exakt auf einem Roboter Messsystem reproduziert, worauf die Messung der in situ Kraft des LCA mittels des Prinzips der Superposition erfolgte. Die jeweiligen Maxima der Kraftaufnahme lagen bei “BW only“ bei 15° mit 33 +/- 11 N (Durchschnitt +/- Standardfehler), bei “ITT“ bei 25° mit 35+/- 5 N und bei “ATF“ bei 35° mit 54+/- 10 N .Die Resultate zeigen, dass “ATF“ die in situ Kraft des LCA im Flexionsbereich 0-55° signifikant um bis zu 60% erhöht (p<0,04), wohingegen das Anbringen von 5 Nm internem Drehmoment nicht zu einer signifikanten Änderung führte (p>0,05). Das Ausmaß der LCA Kraft verringerte sich mit der Erhöhung des Flexionswinkels für alle drei Belastungszustände; somit beeinflusste der Flexionswinkel signifikant die Kraftaufnahme (p<0,001). Diese Daten legen den Schluss nahe, dass das vordere Kreuzband als Widerstand von externen anterioren Translationen dient, jedoch für die Limitierung der internen Rotation keinen signifikanten Effekt zu haben scheint. de_DE
dc.description.abstract This study determined in-vitro anterior cruciate ligament (ACL) force patterns and investigated the effect of external tibial loads on the ACL force patterns during simulated weight-bearing knee flexions. Nine human cadaveric knee specimens were mounted on a dynamic knee simulator, and weight-bearing knee flexions with a 100N of ground reaction force were simulated; while a robotic/ universal force sensor (UFS) system was used to provide external tibial loads during the movement. Three external tibial loading conditions were simulated, including no external tibial load (" BW only 100 N), a 50 N anterior tibial force ("ATF"), and a 5 Nm internal rotation tibial torque (ITT). The tibial and femoral kinematics was measured with an ultrasonic motion capture system. These movement paths were then accurately reproduced on a robotic testing system, and the in-situ force in the ACL was determined via the principle of superposition. The maximum forces under "BW only 100 N) were reached at 15° with 33 +/- 11 N (mean + standard deviation), under "ITT" at 25° with 35+/- 5 N and under "ATF" at 35° with 54+/- 10 N. The results showed that the "ATF" significantly increased the in-situ ACL force by up to 60% during 0–55° of flexion (p<0,04), while the "ITT" did not (p>0.05). The magnitude of ACL forces decreased with increasing flexion angle for all loading conditions. The flexion angle significantly affected the in-situ ACL force (p<0,001) These data indicate that, in a weight-bearing knee flexion, ACL provides substantial resistance to the externally applied ATF but not to the ITT. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Ligamentum cruciatum anterius , Kreuzband , Schienbein de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Kraftaufnahme , Gewichtsbelastung , Kiniekinemator , Roboter/ UFS Messsystem de_DE
dc.subject.other Anterior cruciate ligament , Force , Weightbearing , Kneekinemator , Robotic/ UFS System en
dc.title Kraftaufnahme des vorderen Kreuzbands in einer gewichtssimulierten Flexion unter anteriorer Translations- und interner Rotationsbelastung der Tibia. Eine neue Methode zur Quantifizierung von dynamischen Belastungen de_DE
dc.title Forces in anterior cruciate ligament during simulated weightbearing flexion with anterior translational and internal rotational load of the tibia. A new method to quantify dynamic loads en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2011-04-21 de_DE
utue.publikation.fachbereich Medizin de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 5636 de_DE
thesis.grantor 4 Medizinische Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige