Ein Vergleich gemessener und mit Monte-Carlo Verfahren berechneter Dosisverteilungen bei Schrägeinfall von Elektronen

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Christ, Gunter (Prof. Dr.) de_DE
dc.contributor.author Schweizer, Frederic Michael de_DE
dc.date.accessioned 2009-09-11 de_DE
dc.date.accessioned 2014-03-18T09:41:41Z
dc.date.available 2009-09-11 de_DE
dc.date.available 2014-03-18T09:41:41Z
dc.date.issued 2009 de_DE
dc.identifier.other 310675057 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-41820 de_DE
dc.identifier.uri http://hdl.handle.net/10900/45494
dc.description.abstract Schrägeinfall von Elektronenstrahlung ist eine seltene klinische Anwendung, die beispielsweise bei der Bestrahlung der parasternalen Mamma-interna-Lymphknotenregion beim Mammakarzinom Anwendung finden kann. Während bei Photonenstrahlung der Einsatz von 3-D-Bestrahlungsplanungssystemen (BPS) anerkannter Standard ist, ist dies bei Elektronenstrahlung noch eher die Ausnahme. Der Aufwand für Messung, Implementierung und Testung von Basisdaten wird von vielen Anwendern auch aufgrund bekannter Unzulänglichkeiten konventioneller Algorithmen nicht für lohnenswert erachtet. Monte-Carlo basierte BPSe lassen dagegen eine höhere Genauigkeit erwarten. Ziel dieser Arbeit war es, den MC-Algorithmus des BPSs Oncentra Treatment Planning (OTP, Theranostic) in der Anwendung von Schrägeinfall bei Elektronenstrahlung zu testen. Hierzu wurden Messungen mit Simulationsrechnungen für Elektronenenergien von 4 MeV bis 18 MeV verglichen. Während Standardtubusgrößen, auch bei vergrößertem Fokus-Oberflächen-Abstand, noch eine befriedigende Übereinstimmung ergaben, geht diese mit größer werdendem Einfallswinkel, insbesondere bei stark asymmetrisch gelegenen, individuellen Elektronenschablonen mit kleiner Feldöffnung zusehends verloren. Wir verwenden daher weiterhin gemessene Werte anstelle der mit diesem Algorithmus berechneten Dosisverteilungen und Dosiswerten. de_DE
dc.description.abstract Oblique incidence of electron beams is a rare clinical application which can be used e.g. at the irradiation of the internal mammary lymph nodes in the case of mamma carcinoma. 3-D treatment planning systems are accepted standard for photon beams but not for electron beams. The investment for measuring, implementing and testing basic data seems many customers not to be worthwhile when considering the well known inaccuracies of conventional algorithms. From Monte-Carlo (MC) based algorithms however higher accuracies can be expected. It was the aim of this paper to test the MC algorithm of the treatment planning system Oncentra Treatment Planning (OTP, Theranostic) in the application for oblique incidence of electron beams. Measured and simulated values are compared for electron energies from 4 MeV up to 18 MeV. For standard electron applicators, even at extended source-surface distances, satisfying results are achieved. However, the agreement gets lost with increasing oblique incidence, especially for small individual and asymmetrical cut outs. We therefore still use measured values instead of simulated dose distributions. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Elektronenstrahlung de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Schrägeinfall , Bestrahlungsplanung , Monte - Carlo - Algorithmen de_DE
dc.subject.other Electronbeams , Oblique incidence , Treatment planning , Monte-Carlo algorithms en
dc.title Ein Vergleich gemessener und mit Monte-Carlo Verfahren berechneter Dosisverteilungen bei Schrägeinfall von Elektronen de_DE
dc.title A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2008-11-18 de_DE
utue.publikation.fachbereich Sonstige de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 4182 de_DE
utue.publikation.source Zeitschrift für Medizinische Physik de_DE
thesis.grantor 05/06 Medizinische Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige