Klinisch-experimenteller in vivo Vergleich der herzfrequenzmodulierten zwei- und dreidimensionalen Fetalechokardiographie

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Meyer-Wittkopf, Matthias (Prof. Dr.) de_DE
dc.contributor.author Utz, Simone Franziska de_DE
dc.date.accessioned 2008-11-06 de_DE
dc.date.accessioned 2014-03-18T09:40:28Z
dc.date.available 2008-11-06 de_DE
dc.date.available 2014-03-18T09:40:28Z
dc.date.issued 2008 de_DE
dc.identifier.other 287718581 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-36073 de_DE
dc.identifier.uri http://hdl.handle.net/10900/45323
dc.description.abstract Studienziel: In der vorliegenden Arbeit sollte die sogenannte STIC-Technologie zur dreidimensionalen Darstellung des fetalen Herzens im Hinblick auf ihre Validität und Praktikabilität untersucht werden. Methode: Es wurden 28 Schwangere (29 Feten) zwischen der 19. und 22. Schwangerschaftswoche, die im Rahmen der erweiterten Ultraschalldiagnostik (II. Fehlbildungsscreening) von ihrer betreuenden Frauenärztin / ihrem betreuenden Frauenarzt an die Frauenklinik Tübingen überwiesen wurden, in die Studie eingeschlossen. Sie erhielten nach einer konventionellen zweidimensionalen Ultraschalluntersuchung die dreidimensionale Darstellung des fetalen Herzens mittels der STIC-Technik. Es folgte die Bearbeitung der aufgenommenen Volumendatensätze und Darstellung sowie Beurteilung der Schnittebenen Vierkammerblick, LVOT, RVOT, Ventrikuläres Septum und Valvuläre Morphologie. Ergebnisse: Schon bei der Auswertung der jeweils ersten / jeweils zweiten / jeweils dritten Volumendatenaufnahmen überwiegen die Benotungen „sehr gut darstellbar“ und „teilweise darstellbar“. Mehrere Volumendatenaufnahmen verbesserten insgesamt die Bewertungen. Trotzdem konnten nicht immer alle gewünschten Schnittebenen optimal dargestellt werden. Schlussfolgerung: Die dreidimensionale Darstellung des fetalen Herzens mittels STIC-Technolgie bietet bei einfacher Handhabung oft qualitativ hochwertige Bilder, reicht jedoch noch nicht an die Güte und Validität der zweidimensionale Fetalechokardiographie durch einen geübten Untersucher heran. de_DE
dc.description.abstract Objective: To assess validity and practicality of the spatio-temporal image correlation (STIC) technology used for the three-dimensional display of the foetal heart. Methods: The study involved 28 pregnant women (29 fetuses) between 19 and 22 weeks of gestation who were referred by their gynaecologist to the University Hospital of Tübingen for further ultrasonic diagnostics regarding fetal abnormalities. After a standard two-dimensional ultrasound examination the three-dimensional display of the fetal heart was performed using STIC technology. The volume datasets were edited and the images of the four chamber view, left ventricular outflow tract (LVOT), right ventricular outflow tract (RVOT), ventricular septum and valvular morphology were assessed. Results: The quality of the first / second / third acquired volume datasets was already sufficient to result in predominantly “very good presentability” and “partly presentable” ratings on a standard scale. Repeated data acquisitions improved the over-all assessment. However, not every desired section plane could always be displayed in an optimal way. Conclusions: The three-dimensional display of the fetal heart using STIC technology is easy to use and often results in high-quality images. However, STIC technology does not reach the quality and validity obtained by two-dimensional fetal echocardiography when carried out by a skilled practitioner. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification B-scan-Ultraschallkardiographie , Dimension 3 , Herzfrequenz , Screening , Ultraschall , Herzkammer , Schwangerenvorsorge de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Vierkammerblick , Fetal , Pränatal de_DE
dc.subject.other Four chamber view , Foetal , Prenatal en
dc.title Klinisch-experimenteller in vivo Vergleich der herzfrequenzmodulierten zwei- und dreidimensionalen Fetalechokardiographie de_DE
dc.title Clinical experimental in vivo comparison of the heart rate-modulated two- and three-dimensional foetal echocardiography en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2006-10-31 de_DE
utue.publikation.fachbereich Sonstige de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 3607 de_DE
thesis.grantor 05/06 Medizinische Fakultät de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige